Insect Integration Relay Seat Belt Warning System Operation

(a) Connect the positive (+) lead from the battery to terminals 1 and 7.

(b) Connect the terminal 7 to terminal 9 through the 3.4-W test bulb.

(c) Connect the negative (-) lead from the battery to terminal 10.

(d) Check that the bulb flushes and the buzzer sounds for 4 - 8 seconds.

(e) Return to step (a) and operate the buzzer again.

(f) Connect the negative (-) lead from the battery to terminal 8.

(g) Check that the buzzer stops sounding.

HINT:

Check the buzzer within a period of 4 to 8 seconds.

If operation is not as specified, replace the relay.