Removal Of Air Flow Meter 1
1. REMOVE NO.4 AIR CLEANER PIPE WITH NO.1 AND NO.2 AIR CLEANER HOSES

2. REMOVE AIR FLOW METER WITH AIR CLEANER CAP
(a) Disconnect the connector.
(b) Remove the three clamps and bolt.
(c) Loosen the clamp and remove the air flow meter with air cleaner cap.
3. REMOVE AIR FLOW METER
(a) Remove the two screws and bracket.
(b) Pry off the lock plate.
(c) Remove the four nuts, lock plates. No.1 air cleaner cover and air cleaner cap.